TotalVisc™ Viscoelastic Solution | Complete Solution. Total Protection

The TotalVisc viscoelastic system is the next generation complete OVD solution, offering both mechanical and chemical protection provided by ClearVisc, dispersive and StableVisc cohesive OVDs.


Total Protection

TotalVisc is unique, in that no other dual pack OVD system in the U.S. provides a unique complete solution that utilizes the protection of sorbitol in both ClearVisc, dispersive and StableVisc, cohesive OVDs.

TotalVisc™ Viscoelastic Solution

ClearVisc logo

Visualize the benefits, experience the difference

ClearVisc is the only dispersive OVD in the U.S. with sorbitol for tissue protection. 

StableVisc logo

Next Generation Protection, Preferred Performance

StableVisc, with sorbitol is the only cohesive OVD in the U.S. offering next generation mechanical and chemical protection.


Free Radicals in Cataract Surgery

Free radicals form in the eye as a result of chemical reactions caused during cataract procedures. They can contribute to corneal damage and possible decompensation, which can lead to post-surgical complications such as a cloudy cornea.

With two dual action formulations, ClearVisc and StableVisc create a strong mechanical barrier and chemical protection, which has been shown in lab studies to provide increased free radical scavenging capabilities compared to other OVDs tested.1,2*

ClearVisc™ and StableVisc with sorbitol chemically bond to free radical particles to provide a high level of free radical scavenging activity.1*

*Compared to ProVisc, Viscoat, Healon Pro, Healon Endocoat, AmVisc, Amvisc Plus

Free Radicals diagram


Largest Fill Volume

TotalVisc leads the U.S. dual pack OVD market in fill volume with 1mL of ClearVisc and 1mL StableVisc.

ClearVisc larger fill volume compared to Viscoat and Healon

1. Erb W., Ayyagari M., Lau G., New Ophthalmic Viscosurgical Device (OVD) with Enhanced Hydroxyl Radical Scavenging Activity. May 2021, Virtual ARVO.
2. Francesco Maugeri, Adriana Maltese, Keith W. Ward & Claudio Bucolo (2007). Hydroxyl Radical Scavenging Activity of a New Ophthalmic Viscosurgical Device, Current Eye Research, 32:2, 105-111, DOI:10.1080/02713680601147716.

TotalVisc™
Order Number TVISC20
ClearVisc™
Order Number DVISC10
Size 1.0mL
Viscosity, cP (at 1s-1 shear rate, 25°C) 40,000
Molecular Weight (Daltons) <1.0 million
Composition 2.5% HA 4% sorbitol
Cohesion Dispersive
Osmolality (mOsm/kg) 330
Cannula Size 25G
StableVisc™
Order Number SVISC10
Size 1.0mL
Viscosity, cP (at 1s-1 shear rate, 25°C) 50,000
Molecular Weight (Daltons) 2.1 million
Composition 1.0% HA, 4% sorbitol
Cohesion Cohesive
Osmolality (mOsm/kg) 340
Cannula Size 27G